Our on-line Knowledge Base contains answers to some of the most common support questions. It has information about all PGR products and was developed to help customers resolve product issues. It is constantly updated, expanded, and refined to ensure that our customers have access to the latest information.

Knowledge Base Search

Search For: In:
Any Word All Words Exact Phrase
Show:
 
Improved calibration process for Ladybug cameras.
Article 251: Improved calibration process for Ladybug cameras.

SUMMARY:
This article describes the improved Ladybug calibration process introduced in July 2006.

APPLICABLE PRODUCTS :
All Spherical Vision Products • 

ANSWER:

In July 2006 Point Grey began shipping Ladybug cameras with improved calibration. This calibration better accounts for the high distortion of the Ladybug lenses and consequently allows better stitching results. Calibration is very important when generating panoramic images because it is used to determine which pixels from 2 of the individual camera sensors within the camera head map to the same output pixel in the panoramic image. At the same time we began shipping as default a panorama sphere radius of 20m (see Related Article below regarding image stitching).

Attached are 3 sample images that show the results of the improved calibration and also the importance of the sphere radius for best results. The images are a cropped region from the panoramic images available on the PGR Ladybug Demo DVD (request DVD) and are of an outdoor scene in downtown Vancouver.

Image1 - shows the pre-July 2006 result, using a 5m sphere that is unsuitable for outdoor use

Image2 - shows the post-July 2006 calibration result with a 5m sphere

Image3 - shows the post-July 2006 calibration result with a 20m sphere; there is noticeable improvement

If there are any concerns about your camera calibration, or you wish to upgrade to the latest calibration, please contact the support team at Point Grey Research.



RELATED ARTICLES :
KB Article 250: Overview of the Ladybug image stitching process
KB Article 334: Updating calibration data for a Ladybug camera


ARTICLE INFO:
Article ID:
251
Published:
10/13/2006 3:40:07 PM
Last Modified:
10/16/2006 2:11:05 PM
Keywords:
calibration, stitching, sphere, Ladybug, quality, blend, alpha,