Our on-line Knowledge Base contains answers to some of the most common support questions. It has information about all PGR products and was developed to help customers resolve product issues. It is constantly updated, expanded, and refined to ensure that our customers have access to the latest information.

Knowledge Base Search

Search For: In:
Any Word All Words Exact Phrase
Show:
 
Vertical bleeding or smearing from a saturated portion of an image.
Article 88: Vertical bleeding or smearing from a saturated portion of an image.

SUMMARY:
It is sometimes possible to see a faint bright line that extends from the bottom of the image to the top of the image, passing through a light-saturated spot. This article describes this effect, called smear, and how to avoid it.

APPLICABLE PRODUCTS :
All CCD-based Camera Products • 

ANSWER:

In the sample image below, a faint bright line can be seen that extends from the bottom to the top of the image, passing through the light saturated spot.



This bleeding effect is called "smearing," and is an undesired signal that appears as a brighter vertical (from top to bottom) stripe emanating from a bright part of the image. Smearing is a common problem in high light intensity settings.

Smear Explained

On the interline transfer CCDs used in many Point Grey cameras, each pixel consists of a light sensitive area, called the photosensor, and a light-shielded area, called the vertical transfer register. The vertical transfer register is used to shift the charge out of the photosensor and off of the sensor. Although vertical transfer cells are approximately 100,000 times less sensitive than the light sensitive region, photons may still tunnel into this area, especially when exposed to very bright light. This tunneling, or leaking, is the source of smear.

During image readout, image pixels are shifted vertically downard, row by row, through the vertical transfer cells to the readout register. If there is any leakage of charge into an area of the vertical transfer register, it will be picked up and shifted downward, so that every pixel above and below the area will contain this extra charge. The result is a relatively bright vertical stripe across the entire image.

Effect of Integration Time and Lens Aperture on Smear

Smear is often more noticeable when using very short (microsecond) shutter times. This is because the amount of charge collected in the light-sensitive area of the CCD varies based on exposure time, whereas the amount of charge that collects in the vertical transfer register is based on the sensor readout rate, which is a constant. With short exposures, the ratio of time integrating in the photosensor to time integrating in the vertical transfer is reduced. This reduced ratio may exacerbate smear.

Another factor that affects smear is the angle that light hits the sensor. Many CCDs use on-chip microlenses that cover each pixel in order to increase sensitivity. When light hitting the sensor is not highly collimated (which is often the case with wide angle lenses), light can be refracted by the outer edges of the lens in such a way that it hits the light-shielded portions of the CCD. 

Reducing Smear

Smear may be addressed by reducing the source of bright light hitting the sensor, reducing the aperture, and using a lens that more effectively collimates light. Other, more specific, measures for reducing smear include the following:

  • Increase shutter (integration) time. This will increase the amount of time light is collected in the photosensors relative to the time in the vertical transfer register.
  • Turn the light source off before and after an exposure by using a mechanical or LCD shutter.
  • Use a pulsed or flashed light source. A pulsed light of 1/10,000 duration is sufficient in most cases to allow an extremely short 100ns exposure without smear effect.
  • Increase light collimation by using a lens with variable aperture and stopping it down (closing the aperture), or using a lens with a smaller aperture. Note that an effect of closing the iris will be darker images.
  • Some cameras have specific mechanisms for reducing smear. For more information, consult your camera's Technical Reference manual.


RELATED ARTICLES :
KB Article 87: Why is my image darker in the corners?
KB Article 70: No depth information computed at the boundaries of large depth discontinuities
KB Article 192: CCD imaging sensor well depth capacity.


ARTICLE INFO:
Article ID:
88
Published:
12:00:00 AM
Last Modified:
8/5/2011 10:03:44 AM
Keywords:
smear, smearing, blooming, bleeding, saturation, vertical line, shift registers, interline transfer, photosensor, aperature, iris
Issue Type:
Normal Use



ARTICLE FEEDBACK:
How useful was this article?
less
more
1
2
3
4
5
Additional comments or suggestions?

Go Back Printable Version Email This Article Bookmark This Article

 
 
 

Point Grey Fly Capture
FlyCapture 2.3 Release 18 is available for download!
Download Software